poplaalways.blogg.se

Vida Dice Not Working
vida dice not working


















One of the customer reported that he came across “Device not found/Device not selected” error when using Volvo VIDA DiCE 2014D diagnostic tool.

Newegg will be responsible for processing RMA and general customer service. The company mainly sells wireless chargers, wireless charging treasures, Bluetooth headsets and other electronic products. The main market is Europe and the United. Updating the internal software (also called firmware) in a DiCE unit is done via VIDA All-in-one or the DiCE Firmware Update application. This assumes that the USB driver has been installed for the DiCE unit, see chapter 2.5 Installation of USB driver for DiCE on page 8.

...vida dice not working

Vida Dice Not Working Download At The

NET Framework 3.5will be loaded and installed , you may need to restart. If already installed, go to the next step.B) Insert the image into the virtual drive (in Windows 10 it is present by default) by double clicking on VIDA2014D.iso .C ) Run cmd from the administrator from the open folder with the image VIDA2014D:– File – Open the command line – Open the command line as an administratorBefore finishing the installation DO NOT close the cmd window , we need it twice.2 . Install and configure Microsoft SQL Server 2008 R2 .Copy / paste into the cmd window and press Enter :“3PP \ Products \ SqlExpress \ SQLEXPR_x86_ENU.exe” / ACTION = Install / IACCEPTSQLSERVERLICENSETERMS / ROLE = AllFeatures_WithDefaults / INSTANCENAME = VIDA / SAPWD = GunnarS3g3 / SECURITYMODE = SQL / SQLSVCACCOUNT = “NT AUTHORITY \ SYSTEM” / BROWSERSVCSTARTUPTYPE = Automatic / TCPENABLED = 1 / HIDECONSOLE / ENU / QSWait until the installation is complete. You can check the correctness of the previous installation in:– Start – All applications – Microsoft SQL Server 2008 R2 – SQL Server Installation Center – Tools – Installed SQL Server features discovery reportThe default browser with the report will open. Look – there are two lines in the table (at the end of No, it should be), close the SQL Server Installation Center .Copy / paste OBE lines to the cmd window and press Enter :“Install \ DVD \ Vida_dvdheader \ Main \ setup.exe”Choose only ONE language (install TWO languages ​​and switch them you can – see Method 2 ).Choose the installation path. It is recommended to leave it as default.Installation takes a long time. You can control in the Task Manager by the activity of the alba process . At the end of the installation, icons appear on the desktop.Select in the pop-up window Internet , then Save , then Close , and again Close .Run 2014A-BD.exe from the administrator. If you changed the default VIDA installation path, change only the LETTER drive in the opened window (if you installed it to the root of another disk / partition). Select Install , VIDA Monitor should start after that , after some time its icon in the tray should have a green arrow instead of a yellow arrow.In the pop-up window of the regular firewall, select Allow access for Java.Start VIDA with the VIDA All-in-One icon on the desktop (or in the Start menu, or right-click on the VIDA Monitor icon in the tray).If Internet Explorer prompts you to select and enable add-ins, enable it.Enter in the field Username : 4 for Europe region (others – 1, 2, 3).Click the Vehicle Profile tab , enter the VIN code. There should be a car. If Write Access is denied – check and enter the VIN code manually (NOT through copy / paste).Disable VIDA eUpdate in the Task Manager on the Startup tab , the Java ™ Platform SE binary line .You can also disable VIDA Monitor from startup and run it as needed from the shortcut to Start – VIDA .Adobe Reader XI, which was installed with VIDA, can be deleted (if you use another application for pdf or not needed).* If the server does not start – after a while on the icon appears red “?”, The fault is the update KB3163018or 1607 AU . Download the archive with the folder jdk , unload VIDA Monitor, delete the folder jdk from C: \ VIDA , unpack downloaded to C: \ VIDA , then reboot the PC. Archive with the necessary, to solve this problem, you can download at the end of the post.* If the Username field is NOT active– the tablet did not work, apply again (after unloading the VIDA Monitor ) carefully following all the conditions, then restart the PC. Another option is to unpack the contents of 2014A-BD.exe into C: \ VIDA by agreeing to the replacement. Start from the administrator C: \ VIDA \ patch \ filldb.cmd (previously unloading the VIDA Monitor ). NET Framework 3.5 , then OK , the. Then click again Close (3) on the Configurator screen.7.In the end select “No, I will restart my computer later”8.Extract the downloaded VIDA 2014A Patch rar file into a new folder.9.Open the folder and execute the “VOLVO_VIDA_2014A” file10.In the window that will open, click Install.Volvo VIDA 2014A Window 10 Installation GuideThere is nothing to install additionally, except as specified in this manual. Also, there is NO need to disable / stop any of the default components in Windows 10 (defender, firewall, etc.).– Control Panel – Programs and Features – Turn Windows features on or offIn the Windows Components window , note.

vida dice not working